بلوک تیغه‌ای

بلوک تیغه‌ای ۷

KP-07

20 × 7 × 20 cm

بلوک تیغه‌ای هفت سانتی‌متری برای پارتیشن‌بندی داخلی، سرویس‌ها و فضاهایی که کمترین اشغال ضخامت و کمترین بار مرده اهمیت دارد.

  • Thermal

    λ = 0.36

    Thermal insulation

  • Acoustic

    36 dB

    Sound insulation

  • Fire

    90 min

    Fire resistance

Specifications

Technical specifications for بلوک تیغه‌ای ۷
Property Value
Nominal dimensions 20 × 7 × 20 cm
Wall thickness 7 cm
Weight each 3.2 kg
Compressive strength 3.5 MPa
Thermal conductivity (λ) 0.36 W/m·K
Thermal resistance (R) 0.194 m²·K/W
Water absorption 15.5 %
Sound reduction 36 dB
Fire resistance 90 min
Void ratio 52 %
Units per m² 25 pcs
Units per pallet 240 pcs
Mortar used 12.5 litres/m²
  • استاندارد ملی ایران ۷
  • مبحث ۸ مقررات ملی ساختمان

Why this product?

بلوک تیغه‌ای هفت سانتی‌متری برای پارتیشن‌بندی داخلی، سرویس‌ها و فضاهایی که کمترین اشغال ضخامت و کمترین بار مرده اهمیت دارد.

عایق حرارتی
38
عایق صوتی
52
مقاومت سازه‌ای
40

Features

  • کمترین وزن در خانواده محصولات
  • برش و شیارزنی آسان برای تأسیسات
  • سطح شیاردار برای چسبندگی بهتر گچ

Applications

  • پارتیشن اتاق‌ها
  • دیوار سرویس بهداشتی
  • کمد و فضای دفن تأسیسات

Solutions this product is used in

Installation

How it is laid

The five points that matter most to how the finished wall performs.

Full installation guide
  1. 1

    Level the bed

    The first course goes on a perfectly level mortar bed. Every millimetre out of true in the first course multiplies up the height of the wall.

  2. 2

    Damp the block, do not soak it

    The surface should be damp so it does not draw water out of the mortar. A soaked block does the opposite and destroys adhesion.

  3. 3

    Fill the bed joint completely

    A partial joint lowers strength and opens a path for sound and heat. With tongue-and-groove, the perpend joint disappears.

  4. 4

    No opening without a lintel

    Even small openings need a lintel. A ceramic lintel also keeps the thermal continuity of the facade.

  5. 5

    A metre and a half a day, at most

    Going higher in one go compresses the fresh mortar in the courses below and throws the wall out of plumb.

Used in

Projects built with this product

Related

Related products

Popular KP-10
عایق حرارتی
45
عایق صوتی
60
مقاومت سازه‌ای
46

بلوک تیغه‌ای

بلوک تیغه‌ای ۱۰

25 × 10 × 20 cm

پرکاربردترین بلوک داخلی

λ
0.33 W/m·K
Weight
4.6 kg
Strength
4 MPa
Popular KW-15
عایق حرارتی
55
عایق صوتی
72
مقاومت سازه‌ای
58

بلوک دیواری

بلوک سفالی ۱۵

25 × 15 × 20 cm

دیوار جداکننده بین واحدها

λ
0.29 W/m·K
Weight
7.8 kg
Strength
5 MPa
Popular KW-20
عایق حرارتی
68
عایق صوتی
80
مقاومت سازه‌ای
72

بلوک دیواری

بلوک سفالی ۲۰

40 × 20 × 20 cm

استاندارد صنعت ساختمان ایران

λ
0.26 W/m·K
Weight
11.5 kg
Strength
6.5 MPa